Material
Safety Data Sheet |
 |
Manufactured
by: Starna Scientific Ltd
52/54 Fowler Road,
Hainault,
Essex,
England.
Phone: +44 (0)20 8501 5550.
Date of preparation:31 July 2007.
Prepared by: John P. Hammond CSci CChem FRSC |
Reference Cell contains:
‘HEX’ Reference Cell contains:
Less than 3 ml of n-Hexane
‘TOL/HEX’ Reference Cell contains:
Less than 3 ml of n-Hexane containing less than 200 ppm Toluene |
| CAS No: 110-54-3 |
| Under USA regulations, MSDSs are not required for these materials, and the information provided below is additional safety data as a service to our customers. Our reference cells are a fully-enclosed, manufactured item intended as an end-use product for customers. Therefore, our ‘sealed-cell’ references are not classified as a "hazardous chemical" and are not treated as such under the U.S. OSHA Hazardous Communications Rule. ‘Sealed-cell’ references are considered "articles" within the meaning of 29 CFR Section 1910.1200(c), since they are formed to a specific shape or design during manufacture, have an end-use dependent upon their shape or design, and do not release or otherwise result in exposure to hazardous chemicals under normal conditions of use. |
| Route of Entry - Inhalation: no (sealed cells). |
| Route of Entry - Skin: no (sealed cells). |
| Route of Entry - Ingestion:no (sealed cells). |
| Health Hazard acute and chronic: Due to the small size and volume of the sealed cells and the complete sealing of the materials in quartz cells the only contact that can be made to the chemicals is through the breakage of the cells. The quartz shards would be more hazardous and must be handled as with any glass breakage. |
| Signs and symptoms of exposure: none. |
| Medical Conditions aggravated by exposure: none. |
Under normal circumstances no measures are required for contact with the quartz cell.
In the event of breakage of any of cells, wash with water and safely dispose of the quartz pieces.
If contact is made with the cell liquid by breakage of the cell, the following apply. |
| Inhalation: Remove to fresh air. If not breathing, give artificial respiration. If breathing is difficult, give oxygen. Get medical attention immediately. |
| Ingestion: If swallowed, DO NOT INDUCE VOMITING. Give large quantities of water. Never give anything by mouth to an unconscious person. Get medical attention immediately. |
| Skin Contact: Immediately flush skin with plenty of water for at least 15 minutes while removing contaminated clothing. Get medical attention immediately. |
| Eye contact : Immediately flush eyes with plenty of water for at least 15 minutes, lifting lower and upper eyelids occasionally. Get medical attention immediately. |
| In the event of the heat from a fire causing rupture of the quartz cell, the small volumes of the cell contents involved would not contribute to the incident or add any significant risk, and the measures shown below are for reference if the material is involved in a larger conflagration. |
| Suitable extinguishing agents: Carbon Dioxide, extinguishing powder, or water jet. |
| Protective equipment: Wear full protective clothing, and a self-contained breathing apparatus |
| Ventilate area of leak or spill. Wear appropriate personal protective equipment as specified in section 8. |
| Spill: Due to the small volumes involved and the volatile nature of the contents, it is expected that evaporation will have occurred before any remedial action can be taken. |
| When not being used for measurement, store closed in provided foam filled wooden box. |
| Protect from freezing. |
Under normal use, no protective measures are required.
In the event of a breakage, the following will apply to any liquid released. |
| Respiratory Protection: none required. |
| Ventilation: none required. |
| Protective Gloves: Chemical resistant gloves. |
| Eye Protection: Chemical resistant goggles. |
| Other protective equipment: Have immediate availability of eyewash. |
| Appearance: Transparent liquid heat fusion sealed in a quartz cell, 3ml. |
| Boiling Point: 69 °C. |
| Specific Gravity: 0.66 |
| Vapour Pressure (mm Hg): n/a. |
| Melting Point: -95 °C. |
| Vapour Density: (Air = 1): 3.0 |
| Evaporation Rate: (BuAc = 1): 9 |
| Solubility in Water: Insoluble in water |
| Flash point: -23 °C |
| Flammable limits: air % by volume: lel: 1.2 uel: 7.7 |
| Stability: stable under normal operating conditions. |
| Conditions to avoid: Avoid contact with incompatible materials if broken. |
| Incompatible Materials: Hexane: Strong oxidisers. |
| Hazardous Decomposition Products: |
| Hazardous Polymerization: |
| Not toxic in available volumes. Oral rat LD50: 28710 mg/kg. |
| Carcinogenicity: none known . |
Under normal conditions of use, these ‘sealed-cell’ references do not constitute any risk or hazard to the environment.
If broken, evaporation will quickly remove any risk of liquid contents reaching ground water, water bodies or sewage system. |
| Incineration: Never incinerate ‘sealed-cell’ references. |
| Landfill: Never dispose of ‘sealed-cell’ references as landfill. |
| Recycling: ‘Sealed-cell’ references must be recycled. Contact local Starna dealer for information. Starna Scientific has a recycling protocol for all types of returned ‘sealed-cell’ references. |
Land transport ARD/RID and GGVS/GGVE (cross-border/domestic)
ADR/RID-GGVS/E Class:None |
| Maritime transport IMDG/GGVSea
IMDG/GGVSea Class:None |
Air transport ICAO-TI and IATA-DGR
ICAO/IATA Class: None |
| Designed according to EC guidelines:
Observe the normal safety regulations when handling chemicals.
This ‘sealed-cell’ reference is not subject to classification according to EC lists and other sources of literature known to us.
The product is not subject to identification regulations under EC Directives and the Ordinance on Hazardous Materials (German GefStoffV). |
| Other: none. |
| Disclaimer: This information has been compiled from sources considered to be dependable and is, to the best of our knowledge and belief, accurate and reliable as of the date compiled. However, no representation, warranty (either expressed or implied) or guarantee is made to the accuracy, reliability or completeness of the information contained herein. This information relates to the specific material designated and may not be valid for such material used in combination with any other materials or in any process. It is the user’s responsibility to satisfy themselves as to the suitability and completeness of this information for their own particular use. We do not accept liability for any loss or damage that may occur, whether direct, indirect, indirect, incidental or consequential, from the use of this information nor do we offer warranty against patent infringement. Additional information is available by calling the telephone number above designated for this purpose |
| |
|
|